control cable with xlpe insulation

control cable with xlpe insulation

this product is mainly designed for controlling monitoring circuits and protective lines with ac rated voltage u0/u of 450/750v and 0.6/1kv. it is used to interconnect electric advices and instruments between electrical equipment. it is used for distribution of electricity control and electric control of power stations.

loading port payment termstt or lc min order qty

details

executive standard

gb/t 9330-2008company standard and customer needs

working conditions

1.the long-term allowable working temperature of xlpe insulated should be not exceeding 90℃.

2the temperature when cable laying should be not less than0℃

3.xlpe insulated control cable minimum bend radius non-armoured cable shall be not less than 8 times the cable diameter times. any armor or shield cables shall be not less than 12 times the cable diameter times

4.the laying of cable is not limited by the level drops.

type description and appliion occasion

type description appliion kyjv xlpe insulated pvc sheathed control cable apply to indoors trenches ducts for fixed installation. kyjvp xlpe insulated pvc sheathed woven shield control cable apply to indoors trenches ducts for fixed installation should be shield occasions. kyjvp2 xlpe insulated pvc sheathed copper tape shield control cable kyjvp3 xlpe insulated pvc sheathed aluminum-plastic composite belt shielded control cable kyjv22 xlpe insulated pvc sheathed steel tape armored control cable apply to indoors trenches ducts direct burial be able to withstand large mechanical force and shield loions for installation. kyjvp2-22 xlpe insulated pvc sheathed copper tape shield steel tape armored control cable apply to indoors trenches ducts direct burial be able to withstand large mechanical force and shield loions for installation. kyjv32 xlpe insulated pvc sheathed copper tape shield thin round steel armored control cable apply to indoors trenches ducts direct burial be able to withstand large mechanical and for certain pulling force. for fixed installation. kyjy xlpe insulated pe sheathed control cable apply to indoors trenches ducts for fixed installation. kyjyp xlpe insulated pe sheathed woven shield control cable apply to indoors trenches ducts for fixed installation should be shield occasions. kyjyp2 xlpe insulated pe sheathed copper tape shield control cable kyjyp3 xlpe insulated pe sheathed aluminum-plastic composite belt shielded control cable kyjy23 xlpe insulated pe sheathed steel tape armored control cable apply to indoors trenches ducts direct burial be able to withstand large mechanical force and shield loions for installation. kyjyp2-23 xlpe insulated pe sheathed copper tape shield steel tape armored control cable apply to indoors trenches ducts direct burial be able to withstand large mechanical force and shield loions for installation. kyjy33 xlpe insulated pe sheathed control cable apply to indoors trenches ducts direct burial be able to withstand large mechanical and for certain pulling force. for fixed installation.

note

1we also provide flame retardant type and fire resistant type cables. prefix lsquoz- means flame retardant type lsquon- means fire resistant type.

2commonly used type listed in this table refer item 6 for more types.

production scope

type rated voltage conductor nominal section /mm2 0.5 0.75 1 1.5 2.5 4 6 10 number of cores kyjv kyjvp 450/750v0.6/1kv --- 2-61 2-14 2-10 kyjy kyjyp kyjvp2 kyjvp3 --- 4-61 4-14 4-10 kyjyp2 kyjyp3 kyjv22 kyjv23 --- 7-61 4-61 4-14 4-10 kyjvp2-22 --- 7-61 4-61 4-14 4-10 kyjyp2-22 kyjv32 kyjy33 --- 19-61 7-61 4-14 4-10 kyjvr 2-61 --- kyjvrp 2-61 2-48 ---
product code name and description
item code description flame-retardant / there is no letter for non-flame-retardant type zr flame retardant type zra flame retardant rating a zrb flame retardant rating b zrc flame retardant rating c ddz low-halogen low-smoke flame retardant wdz halogen free low-smoke flame retardant see flame retardant fire resistant list for more detail series k control cable insulating material yj xlpe sheathing material v pvc y y screening material / non-screening p copper wire shield p1 tinned copper wire shield p2 copper tape p3 aluminum-plastic composite tape armoring material 22 steel tape 32 thin steel wire conductor structure r stranded soft core and a stands for single strand conductor while b stands for seven-strand twisted conductor. specifiion / core number cross cection of conductorns core numbern2345helliphellip61 cross cections0.50.751.01.52.54610mm2