06 1kv power cable with xlpe insulation

06 1kv power cable with xlpe insulation

the product is suitable for power transmission and distribution lines with rated voltage up to including 0.6/1kv.

loading port payment termstt or lc min order qty

details

executive standard

gb/t 12706-2008equal to the standard of iec 605022004 we also provide products according to the stand of bsdin and icea upon request.

working conditions

1long-term working temperature allowed by cable conductor shall be no higher than 90℃

2max. temperature of cable conductor shall be no higher than 250℃ during short circuit the longest lasting time shall be no more than 5 seconds overload temperature shall be no higher than 130℃

3environment temperature for laying shall be no lower than 0℃ min bending radius single core cables 20d mm multiple core cables 15d mm d represents actual outer diameter.

type description and appliion occasion

type

description appliion occasion cu al yjv yjlv xlpe insulated and pvc sheathed power cables for laying indoors in tunnel and in cable trench unable to bear external mechanical forces. single core cable in magnetic duct is not permissible. yjy yjly xlpe insulated and pe sheathed power cables yjv22 yjlv22 xlpe insulated steel tape armored and pvc sheathed power cables for laying in doors in tunnels and in cable trench able to bear external mechanical forces but unable to bear large pulling force. yjv23 yjlv23 xlpe insulated steel tape armored and pe sheathed power cables yjv32 yjlv32 xlpe insulated thin round steel wire armored and pvc sheathed power cables for laying in doors in tunnel and cable trench and wells able to bear external mechanical forces and certain pulling force. yjv33 yjlv33 xlpe insulated thin round steel wire armored and pe sheathed power cables

note

1we also provide flame retardant type and fire resistant type power cables. prefix lsquoz- means flame retardant type lsquon- means fire resistant type.

2commonly used type listed in this table see item 5 for more types.

production scope

type

core number mm2 cu lv nominal cross-section area yjv yjy --

1

1.0 800 -- yjlv yjly 2.5 800 yjv22 yjv23 yjlv22 yjlv23 10 800 yjv yjy --

2

1.0 300 -- yjlv yjly 2.5 300 yjv22 yjv23 yjlv22 yjlv23 4.0 300 yjv32 yjv33 yjlv32 yjlv33 10 300 yjv yjy --

3

1.0 400 -- yjlv yjly 2.5 400 yjv22 yjv23 yjlv22 yjlv23 4.0 400 yjv32 yjv33 yjlv32 yjlv33 10 400 yjv yjy --

4

1.0 400 -- yjlv yjly 2.5 400 yjv22 yjv23 yjlv22 yjlv23 4.0 400 yjv32 yjv33 yjlv32 yjlv33 10 400 yjv yjy --

31

1.0 400 yjv22 yjv23 yjlv yjly yjlv22 yjlv23 4.0 400 yjv32 yjv33 yjlv32 yjlv33 10 400 yjv yjy --

5

1.0 400 -- yjlv yjly 2.5 400 yjv22 yjv23 yjlv22 yjlv23 4.0 400 yjv32 yjv33 yjlv32 yjlv33 10 400 yjv yjy --

41

1.0 400 yjv22 yjv23 yjlv yjly yjlv22 yjlv23 4.0 400 yjv32 yjv33 yjlv32 yjlv33 10 400 yjv yjy --

32

1.0 400 yjv22 yjv23 yjlv yjly yjlv22 yjlv23 4.0 400 yjv32 yjv33 yjlv32 yjlv33 10 400

note

the armoured single core cables are used for d. e. system only. as for a. c. system non-magnetic armour material should be used or a magnetic isolation should be applied.

model number definition

insulation

conductors

inner coverings

armour

over sheath

code materials code materials code materials code materials code materials v pvc t class 2 v pvc 2 double tape 2 pvc yj xlpe r class 5 y pe 3 thin steel wire 3 pe e epr l al f elastomer 4 thick steel wire 4 elastomer ey hepr q lead sheath 6 7

packing

product line